Constant temperature control of tundish induction heating power supply for metallurgical manufacturing

Yufei YUE, Qianming XU, Peng GUO, An LUO

《能源前沿(英文)》 2019年 第13卷 第1期   页码 16-26 doi: 10.1007/s11708-018-0572-0

摘要: The tundish induction heating power supply (TIHPS) is one of the most important equipment in the continuous casting process for metallurgical manufacturing. Specially, the constant temperature control is greatly significant for metallurgical manufacturing. In terms of the relationship between TIH load temperature and output power of TIHPS, the constant temperature control can be realized by power control. In this paper, a TIHPS structure with three-phase PWM rectifiers and full-bridge cascaded inverter is proposed. Besides, an input harmonic current blocking strategy and a load voltage feedforward control are also proposed to realize constant temperature control. To meet the requirement of the system, controller parameters are designed properly. Experiments are conducted to validate the feasibility and effectiveness of the proposed TIHPS topology and the control methods.

关键词: tundish induction heating power supply (TIHPS)     constant temperature control     input harmonic current blocking     load voltage feedforward    

Experimental investigation and comparative study of inter-turn short-circuits and unbalanced voltage supplyin induction machines

Fatima BABAA, Abdelmalek KHEZZAR, Mohamed el kamel OUMAAMAR

《能源前沿(英文)》 2013年 第7卷 第3期   页码 271-278 doi: 10.1007/s11708-013-0258-6

摘要: A transient model for an induction machine with stator winding turn faults on a single phase is derived using reference frame transformation theory. The negative sequence component and the 3rd harmonic are often considered as accurate indicators. However, small unbalance in the supply voltage and/or in the machine structure that exists in any real system engenders the same harmonics components. In this case, it is too difficult to distinguish between the current harmonics due to the supply voltage and those originated by inter-turn short-circuit faults. For that, to have the correct diagnosis and to increase the sensitivity and the reliability of the diagnostic system, it is crucial to provide the relationship between the inter-turn short-circuits in the stator winding and the supply voltage imbalance through an accurate mathematical model and via a series of experimental essays.

关键词: induction machines     fault indicator     inter-turn short-circuit fault     unbalance supply voltage    

Toward a nonlinear control of an AC-DC-PWM converter dedicated to induction heating

Amel HADRI-HAMIDA, S. ZEROUALI, A. ALLAG

《能源前沿(英文)》 2013年 第7卷 第2期   页码 140-145 doi: 10.1007/s11708-013-0243-0

摘要: In this paper, a nonlinear control strategy applied to an AC-DC-pulse width modulation (PWM) converter is developed and simulated. First a nonlinear system modeling is derived with state variables of the input current and the output voltage by using power balance of the input and output. The system is linearized and decoupled, and then a state feedback law is obtained. For robust control of parameter perturbation, integrators are added to the exact feedback control law. The simulation is provided to verify the validity of the control algorithm.

关键词: DC-DC converter     AC-DC-pulse width modulation (PWM) converter     induction heating     nonlinear control    

Fault simulation of boiler heating surface ash deposition in a power plant system

Weiwei ZHANG, Huisheng ZHANG, Ming SU

《能源前沿(英文)》 2011年 第5卷 第4期   页码 435-443 doi: 10.1007/s11708-011-0162-x

摘要: The simulation model of a power generation system was developed based on EASY5 simulation platform. The performances of the power plant under the conditions of the furnace slagging and ash deposition of the heating surfaces in the boiler were simulated. The results show that the simulation model can reasonably reflect the characteristics of the power plant when each component is under fault conditions. Through fault simulation, the change of the performance parameters can be obtained, which can be used in fault diagnosis system as the diagnosis criterion for expert system.

关键词: boiler     slagging     ash deposition     fault simulation    

Estimation of composite load model with aggregate induction motor dynamic load for an isolated hybridpower system

Nitin Kumar SAXENA,Ashwani Kumar SHARMA

《能源前沿(英文)》 2015年 第9卷 第4期   页码 472-485 doi: 10.1007/s11708-015-0373-7

摘要: It is well recognized that the voltage stability of a power system is affected by the load model and hence, to effectively analyze the reactive power compensation of an isolated hybrid wind-diesel based power system, the loads need to be considered along with the generators in a transient analysis. This paper gives a detailed mathematical modeling to compute the reactive power response with small voltage perturbation for composite load. The composite load is a combination of the static and dynamic load model. To develop this composite load model, the exponential load is used as a static load model and induction motors (IMs) are used as a dynamic load model. To analyze the dynamics of IM load, the fifth, third and first order model of IM are formulated and compared using differential equations solver in Matlab coding. Since the decentralized areas have many small consumers which may consist large numbers of IMs of small rating, it is not realistic to model either a single large rating unit or all small rating IMs together that are placed in the system. In place of using a single large rating IM, a group of motors are considered and then the aggregate model of IM is developed using the law of energy conservation. This aggregate model is used as a dynamic load model. For different simulation studies, especially in the area of voltage stability with reactive power compensation of an isolated hybrid power system, the transfer function of the composite load is required. The transfer function of the composite load is derived in this paper by successive derivation for the exponential model of static load and for the fifth and third order IM dynamic load model using state space model.

关键词: isolated hybrid power system (IHPS)     composite load model     static load     dynamic load     induction motor load model     aggregate load    

Analysis and control of wind-driven self-excited induction generators connected to the grid through power

S. Senthil KUMAR, N. KUMARESAN, N. Ammasai GOUNDEN, Namani RAKESH

《能源前沿(英文)》 2012年 第6卷 第4期   页码 403-412 doi: 10.1007/s11708-012-0208-8

摘要: The analysis of the wind-driven self-excited induction generators (SEIGs) connected to the grid through power converters has been developed in this paper. For this analysis, a method of representing the grid power as equivalent load resistance in the steady-state equivalent circuit of SEIG has been formulated. The technique of genetic algorithm (GA) has been adopted for making the analysis of the proposed system simple and straightforward. The control of SEIG is attempted by connecting an uncontrolled diode bridge rectifier (DBR) and a line commutated inverter (LCI) between the generator terminals and three-phase utility grid. A simple control technique for maximum power point tracking (MPPT) in wind energy conversion systems (WECS), in which the firing angle of the LCI alone needs to be controlled by sensing the rotor speed of the generator has been proposed. The effectiveness of the proposed method of MPPT and method of analysis of this wind-driven SEIG-converter system connected to the grid through power converters has been demonstrated by experiments and simulation. These experimental and simulated results confirm the usefulness and successful working of the proposed system and its analysis.

关键词: self-excited induction generator (SEIG)     renewable power generation     power converters     maximum power point tracking (MPPT)     steady state analysis     power generation systems    

Application of fuzzy logic control algorithm as stator power controller of a grid-connected doubly-fedinduction generator

Ridha CHEIKH, Arezki MENACER, Said DRID, Mourad TIAR

《能源前沿(英文)》 2013年 第7卷 第1期   页码 49-55 doi: 10.1007/s11708-012-0217-7

摘要: This paper discusses the power outputs control of a grid-connected doubly-fed induction generator (DFIG) for a wind power generation systems. The DFIG structure control has a six diode rectifier and a PWM IGBT converter in order to control the power outputs of the DFIG driven by wind turbine. So, to supply commercially the electrical power to the grid without any problems related to power quality, the active and reactive powers ( , ) at the stator side of the DFIG are strictly controlled at a required level, which, in this paper, is realized with an optimized fuzzy logic controller based on the grid flux oriented control, which gives an optimal operation of the DFIG in sub-synchronous region, and the control of the stator power flow with the possibility of keeping stator power factor at a unity.

关键词: doubly-fed induction generator (DFIG)     vector control     fuzzy logic controller     optimization     power factor unity     active and reactive power    

Multiple target implementation for a doubly fed induction generator based on direct power control under

Heng NIAN,Yi-peng SONG

《信息与电子工程前沿(英文)》 2015年 第16卷 第4期   页码 321-334 doi: 10.1631/FITEE.1400170

摘要: This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional and integral (PI) regulator is adopted to regulate the DFIG average active and reactive powers, while the vector PI (VPI) resonant regulator is used to achieve three alternative control targets: (1) balanced and sinusoidal stator current; (2) smooth instantaneous stator active and reactive powers; (3) smooth electromagnetic torque and instantaneous stator reactive power. The major advantage of the proposed control strategy over the conventional method is that neither negative and harmonic sequence decomposition of grid voltage nor complicated control reference calculation is required. The insensitivity of the proposed control strategy to DFIG parameter deviation is analyzed. Finally, the DFIG experimental system is developed to validate the availability of the proposed DPC strategy under unbalanced and distorted grid voltage.

关键词: Direct power control     Doubly fed induction generator     Unbalanced and distorted grid voltage     Vector proportional and integral resonant regulator     Parameter deviation    

A comprehensive energy solution for households employing a micro combined cooling, heating and power

Huayi ZHANG, Can ZHANG, Fushuan WEN, Yan XU

《能源前沿(英文)》 2018年 第12卷 第4期   页码 582-590 doi: 10.1007/s11708-018-0592-9

摘要:

In recent years, micro combined cooling, heating and power generation (mCCHP) systems have attracted much attention in the energy demand side sector. The input energy of a mCCHP system is natural gas, while the outputs include heating, cooling and electricity energy. The mCCHP system is deemed as a possible solution for households with multiple energy demands. Given this background, a mCCHP based comprehensive energy solution for households is proposed in this paper. First, the mathematical model of a home energy hub (HEH) is presented to describe the inputs, outputs, conversion and consumption process of multiple energies in households. Then, electrical loads and thermal demands are classified and modeled in detail, and the coordination and complementation between electricity and natural gas are studied. Afterwards, the concept of thermal comfort is introduced and a robust optimization model for HEH is developed considering electricity price uncertainties. Finally, a household using a mCCHP as the energy conversion device is studied. The simulation results show that the comprehensive energy solution proposed in this work can realize multiple kinds of energy supplies for households with the minimized total energy cost.

关键词: energy hub     micro combined cooling     heating and power generation (mCCHP)     thermal comfort     robust optimization    

Will Germany move into a situation with unsecured power supply?

Harald SCHWARZ

《能源前沿(英文)》 2019年 第13卷 第3期   页码 551-570 doi: 10.1007/s11708-019-0641-z

摘要: Together with a huge number of other countries, Germany signed the Paris Agreements in 2015 to prevent global temperature increase above 2°C. Within this agreement, all countries defined their own national contributions to CO reduction. Since that, it was visible that CO emissions in Germany decreased, but not so fast than proposed in this German nationally determined contribution to the Paris Agreement. Due to increasing traffic, CO emissions from this mobility sector increased and CO emission from German power generation is nearly constant for the past 20 years, even a renewable generation capacity of 112 GW was built up in 2017, which is much higher than the peak load of 84 GW in Germany. That is why the German National Government has implemented a commission (often called “The German Coal Commission”) to propose a time line: how Germany can move out of coal-fired power stations. This “Coal Commission” started its work in the late spring of 2018 and handed over its final report with 336 pages to the government on January 26th, 2019. Within this report the following proposals were made: ① Until 2022: Due to a former decision of the German Government, the actual remaining nuclear power generation capacity of about 10 GW has to be switched off in 2022. Besides, the “Coal Commission” proposed to switch off additionally in total 12.5 GW of both, hard coal and lignite-fired power plants, so that Germany should reduce its conventional generation capacity by 22.5 GW in 2022. ② Until 2030: Another 13 GW of German hard coal or lignite-fired power plants should be switched off. ③ Until 2038: The final 17 GW of German hard coal or lignite-fired power plants should be switched off until 2038 latest. Unfortunately the “Coal Commission” has not investigated the relevant technical parameter to ensure a secured electric power supply, based on German’s own national resources. Because German Energy Revolution mainly is based on wind energy and photovoltaic, this paper will describe the negligible contribution of these sources to the secured generation capacity, which will be needed for a reliable power supply. In addition, it will discuss several technical options to integrate wind energy and photovoltaic into a secured power supply system with an overall reduced CO emission.

关键词: CO2 reduction     mobility sector     renewable generation     coal commission     secured power generation capacity     reliable power supply     power-to-gas     power-to-heat    

A unified power electronic controller for wind driven grid connected wound rotor induction generator

D. R. BINU BEN JOSE, N. AMMASAI GOUNDEN, Raavi SRI NAGA RAMESH

《能源前沿(英文)》 2013年 第7卷 第1期   页码 39-48 doi: 10.1007/s11708-012-0229-3

摘要: The implementation of a simple power converter for a wound rotor induction generator employing a three phase diode bridge rectifier and a line commutated inverter in the rotor circuit for super synchronous speeds has been proposed. The detailed working of the system in power smoothing mode and maximum power point tracking mode is presented. The current flow in the rotor circuit is controlled (by controlling the firing angle of the line commutated inverter) for controlling the stator power in both the modes. An 8 bit PIC microcontroller has been programmed to vary the firing angle of the line commutated inverter. Experiments have been carried out on a 3-phase, 3.73 kW, 400 V, 50 Hz, 4-pole, 1500 r/min wound rotor induction generator and the results obtained with the generator supplying power in both the modes are furnished. The complete scheme has been modeled using MATLAB/SIMULINK blocks and a simulation study has been conducted. The experimental waveforms are compared with the simulation results and a very close agreement between them is observed.

关键词: line commutated inverter     MPPT     power smoothing     wound rotor induction generator    

Robust control based on the Lyapunov theory of a grid-connected doubly fed induction generator

Ridha CHEIKH, Arezki MENACER, Said DRID

《能源前沿(英文)》 2013年 第7卷 第2期   页码 191-196 doi: 10.1007/s11708-013-0245-y

摘要: This paper discusses the robust control of a grid-connected doubly-fed induction generator (DFIG) controlled by vector control using a nonlinear feedback linearization strategy in order to ameliorate the performances of the control and to govern the developed stator active and reactive power in a linear and decoupled manner, in which an optimal operation of the DFIG in sub-synchronous operation is given, as well as the control stator power flow with the possibility of keeping stator power factor at a unity. The use of the state-all-flux induction machine model gives place to a simpler control model. So, to achieve this objective, the Lyapunov approach is used associated with a sliding mode control to guarantee the global asymptotical stability and the robustness of the parametric variations.

关键词: doubly fed induction generator (DFIG)     vector control     Lyapunov function     power factor unity     active power     reactive power    

Local arc discharge mechanism and requirements of power supply in micro-arc oxidation of magnesium alloy

Ming CHEN, Yuezhou MA, Yuan HAO,

《机械工程前沿(英文)》 2010年 第5卷 第1期   页码 98-105 doi: 10.1007/s11465-009-0088-8

摘要: To study the requirements of the power supply in micro-arc oxidation (MAO) of magnesium alloy, many experiments were performed under the DC, unipolar, and ambipolar pulse output modes. Based on the experimental results and electric arc theory, the separate local arc discharge mechanism was put forward. It is considered that magnesium MAO process consists of three stages including anodic oxidation, micro-arc oxidation, and large-arc discharge in turn with increasing source voltage. The MAO film is composed of metal oxides that resulted from numerous discrete local arc discharges, which accumulate the non-equilibrium structure after undergoing sudden heating and cooling cycles. Separate local arc discharge is caused by the process in which the oxygen-based gas is ionized in the conduct channel bearing electric field intensity, changed from insulator to conductor that presents sharp negative resistance effect, and produced partially high temperature to ignite locally metal oxidation. The local arc discharge model is described as four courses: gas created from electrolysis, arc discharge, metals oxidization, and cooling and shrinking of oxides. The purpose of pulse supply is to inhibit the large-arc discharge by intervening proper cooling time, which cannot be actualized by a unipolar pulse mode because of the strong capacitive load characteristics but can be reached by an ambipolar pulse supply because the negative pulse period acts as cooling time. Using a discharge loop to remove the influence of load capacitive, a new type of pulse power supply for MAO is developed, so that the large-arc problem is resolved effectively, the film-forming efficiency is improved, and the pollution of the film and electrolyte caused by negative voltage is avoided.

关键词: micro-arc oxidation     local arc discharge     pulse power supply     magnesium alloy    

An improved delta-star switching scheme for reactive power saving in three-phase induction motors

P. RAJA,N. KUMARESAN,M. SUBBIAH

《能源前沿(英文)》 2014年 第8卷 第3期   页码 364-370 doi: 10.1007/s11708-014-0324-8

摘要: It is proposed that a capacitor can be connected permanently across each phase winding of a three-phase induction motor along with the conventional delta-star switching, for further saving in VARh at reduced loads on the motor. The method of choosing a suitable value for the capacitor and the criteria to be adopted for calculating the power output at which the star to delta switching is to be made are also explained. The experimental results on a 3-phase, 4-pole, 415 V, 50 Hz, 3.3 kW induction motor verify the advantages in adding the capacitor to the phase winding of the motor. Compared to using only a single delta connected stator winding or a delta-star switching, the advantages of the proposed addition of a capacitor, are also demonstrated through a case study conducted on a 400 V, 250 kW motor. Any further improvement in grid side power factor can be achieved by employing a static synchronous compensator (STATCOM) of reduced VAR rating.

关键词: delta-star switching     induction motor     power factor     steady-state analysis    

Robust direct power control based on the Lyapunov theory of a grid-connected brushless doubly fed induction

M. Abdelbasset MAHBOUB,Said DRID,M. A. SID,Ridha CHEIKH

《能源前沿(英文)》 2016年 第10卷 第3期   页码 298-307 doi: 10.1007/s11708-016-0411-0

摘要: This paper deals with robust direct power control of a grid-connected brushless doubly-fed induction generator(BDFIG). Using a nonlinear feedback linearization strategy, an attempt is made to improve the desired performances by controlling the generated stator active and reactive power in a linear and decoupled manner. Therefore, to achieve this objective, the Lyapunov approach is used associated with a sliding mode control to guarantee the global asymptotical stability. Thus, an optimal operation of the BDFIG in sub-synchronous operation is obtained as well as the stator power flows with the possibility of keeping stator power factor at a unity. The proposed method is tested with the Matlab/Simulink software. Simulation results illustrate the performances and the feasibility of the designed control.

关键词: brushless doubly fed induction generator (BDFIG)     vector control     Lyapunov theory     power factor unity     active and reactive power    

标题 作者 时间 类型 操作

Constant temperature control of tundish induction heating power supply for metallurgical manufacturing

Yufei YUE, Qianming XU, Peng GUO, An LUO

期刊论文

Experimental investigation and comparative study of inter-turn short-circuits and unbalanced voltage supplyin induction machines

Fatima BABAA, Abdelmalek KHEZZAR, Mohamed el kamel OUMAAMAR

期刊论文

Toward a nonlinear control of an AC-DC-PWM converter dedicated to induction heating

Amel HADRI-HAMIDA, S. ZEROUALI, A. ALLAG

期刊论文

Fault simulation of boiler heating surface ash deposition in a power plant system

Weiwei ZHANG, Huisheng ZHANG, Ming SU

期刊论文

Estimation of composite load model with aggregate induction motor dynamic load for an isolated hybridpower system

Nitin Kumar SAXENA,Ashwani Kumar SHARMA

期刊论文

Analysis and control of wind-driven self-excited induction generators connected to the grid through power

S. Senthil KUMAR, N. KUMARESAN, N. Ammasai GOUNDEN, Namani RAKESH

期刊论文

Application of fuzzy logic control algorithm as stator power controller of a grid-connected doubly-fedinduction generator

Ridha CHEIKH, Arezki MENACER, Said DRID, Mourad TIAR

期刊论文

Multiple target implementation for a doubly fed induction generator based on direct power control under

Heng NIAN,Yi-peng SONG

期刊论文

A comprehensive energy solution for households employing a micro combined cooling, heating and power

Huayi ZHANG, Can ZHANG, Fushuan WEN, Yan XU

期刊论文

Will Germany move into a situation with unsecured power supply?

Harald SCHWARZ

期刊论文

A unified power electronic controller for wind driven grid connected wound rotor induction generator

D. R. BINU BEN JOSE, N. AMMASAI GOUNDEN, Raavi SRI NAGA RAMESH

期刊论文

Robust control based on the Lyapunov theory of a grid-connected doubly fed induction generator

Ridha CHEIKH, Arezki MENACER, Said DRID

期刊论文

Local arc discharge mechanism and requirements of power supply in micro-arc oxidation of magnesium alloy

Ming CHEN, Yuezhou MA, Yuan HAO,

期刊论文

An improved delta-star switching scheme for reactive power saving in three-phase induction motors

P. RAJA,N. KUMARESAN,M. SUBBIAH

期刊论文

Robust direct power control based on the Lyapunov theory of a grid-connected brushless doubly fed induction

M. Abdelbasset MAHBOUB,Said DRID,M. A. SID,Ridha CHEIKH